End Launch Connectors - Installation Procedure

Step 1: Mount the end launch connector on the board in the desired position.

Step 2: Ensure the launch pin is centered on the trace.

Step 3: Ensure the transition block is tight against the board.

Step 4: Tighten the 1-72 mounting screws until the connector is secured.

Step 5 (Optional) : Solder the launch pin to the trace. (Note: Be sure the solder flows the entire length of the launch pin/trace contact area.)

Step 6 (Optional) : Remove any excess solder. (Note: Excess solder will affect performance.)

Step 7 (Optional) : Clean any flux or other residue from around the solder joint.

 


End Launch Boards:
 

 

____________________________________________________________________________________

End Launch Connectors - Dimensions

 

Field Replaceable .375” Square Flange Connectors are Available in Male or Female

Configurations.

 
Standard Profile Connectors:

 

 

 
 
 
 

 

Low Profile Connectors:

 