HASCO Coaxial RF Terminations | DC to 110 GHz, Up to 100 W

HASCO · 50-Ohm RF Loads

Complete Coaxial Termination Series from DC to 110 GHz

Terminate unused RF ports with low-reflection 50-ohm loads across precision millimeter-wave, microwave, blind-mate and higher-power coaxial interfaces.

DC-110 GHz
Coaxial coverage
0.25-100 W
Average-power range
50 Ohms
Matched RF loads
Precision + power terminations
HASCO HT50M 2.4 mm RF termination
HASCO HT40M 2.92 mm RF termination
HASCO HT18M-5 heat-sink RF termination
Compact stainless-steel precision loads and heat-sink terminations support measurement, switching, distribution and deployed RF systems.
Absorb incident RF energy

Close unused ports with the correct matched load.

An unterminated port reflects energy back into the network. A properly selected termination presents a nominal 50-ohm load and dissipates incident power while minimizing the reflection that can disturb measurements, isolation, gain, stability and system performance.

01

Control reflections

Terminate unused ports on switches, couplers, dividers, circulators and test fixtures.

02

Protect RF hardware

Provide a defined load where reflected energy could impair an amplifier or other active stage.

03

Stabilize measurements

Maintain repeatable boundary conditions in VNA, production and subsystem testing.

04

Dissipate power safely

Match average, peak and thermal-derating requirements to the actual signal environment.

Interface guide

Select by connector, frequency and dissipated power.

Maximum frequency and power do not occur in the same model. Precision 1.0 mm loads extend to 110 GHz at 1 W, while Type N heat-sink loads reach 100 W at lower microwave frequencies.

1.0 mm · DC-110 GHz

HT1.0M-1

Male · 1 W · precision mmWave load

1.85 mm · DC-67 GHz

HT65 / HT67 Series

Male and female · 1-2 W

2.4 mm · DC-50 GHz

HT50 Series

Male and female · 1 W listed

2.92 mm · DC-40 GHz

HT40 Series

Male and female · 1-2 W

3.5 mm · DC-34.5 GHz

HT35M-1

Male · 1 W · 1.15:1 VSWR

SMA · DC-26.5 GHz

HT18 / HT20 / HT26 Series

Male, female, quick-mate and thread-in · 1-10 W

TNC · DC-18 GHz

HT18TM-2

Male · 2 W · threaded interface

Type N · DC-18 GHz

N-Type Load Family

Male and female · 2-100 W depending on band

4.3-10 · DC-8.5 GHz

HT4310M Series

Male · 5, 10 and 25 W listings

7/16 DIN · DC-6 GHz

HT716M-25

Male · 25 W · infrastructure interface

SMPM · DC-6 GHz

HT6SMPMF Series

Female · 0.25 or 1 W · blind-mate

Representative family comparison

Frequency rises as the interface becomes smaller; power rises with thermal mass.

Interface Representative models Maximum listed frequency Available gender Representative power
1.0 mm HT1.0M-1 110 GHz Male 1 W
1.85 mm HT65M, HT65F, HT67M-2 67 GHz Male / female 1-2 W
2.4 mm HT50M, HT50F 50 GHz Male / female 1 W listed
2.92 mm HT40M, HT40F, HT40M-2 40 GHz Male / female 1-2 W
3.5 mm HT35M-1 34.5 GHz Male 1 W
SMA HT18, HT20, HT26 families 26.5 GHz Male / female 1-10 W
TNC HT18TM-2 18 GHz Male 2 W
Type N 231/221 Series, HT18NM, HT4NM 18 GHz Male / female 2-100 W
4.3-10 HT4310M Series 8.5 GHz Male 5-25 W
7/16 DIN HT716M-25 6 GHz Male 25 W
SMPM HT6SMPMF / -1 6 GHz Female blind-mate 0.25-1 W

Selection note: frequency, VSWR and power ratings are model-specific. Apply the published thermal derating and peak-power duty-cycle limits for the selected termination.

Engineering selection guide

Specify more than connector and wattage.

Frequency and VSWR

Verify maximum VSWR across the complete operating band, not only at the lowest frequency.

Average and peak power

Check CW dissipation plus pulse width, duty cycle and mismatch conditions.

Thermal environment

Derate for ambient temperature, airflow, mounting and adjacent heat sources.

Mating and mechanics

Confirm gender, torque, durability, blind-mate style, chain or fixed-thread requirements.

HASCO technical and purchasing support

Select the load around the port and the energy it must absorb.

Interface review

Confirm connector series, gender and mating requirements.

Electrical review

Match frequency, VSWR, average power and pulse conditions.

Stock and lead time

Check current inventory and project delivery requirements.

Quality

HASCO is AS9120:B and ISO 9001:2015 certified.

Request a HASCO Coaxial Termination Quote

Include connector series and gender, frequency range, average and peak power, pulse conditions, maximum VSWR, operating temperature, quantity and requested delivery date.